1.You can contact the customer service. for any question regarding the product.
2.Ask the question in English to get answer faster.
3.Keep your question short and to the point.
安全なチェックアウト
AutoVolt automatic ac/dc voltage selection
LoZ: Helps prevent false readings due to ghost voltage
True-rms for accurate measurements on non-linear loadsMeasures 10 A (20 A overload for 30 seconds)Resistance, continuity, frequency and capacitanceMin/Max/Average to record signal fluctuationsCompatible with optional magnetic hanger (ToolPak) for hands free operationCAT III 600 V safety rate
Brand | Fluke 117C |
Mode | Fluke 117C |
Power Source | 9V batteries required. (Not included) |
Style | Multimeter Standard |
Item Weight | 550 Grams |
Item Dimensions LxWxH | 6.57 x 3.31 x 1.81 inches |
Measurement Type | Multimeter |
Measurement Accuracy | u200e+/-0.5% |
Specifications:
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/Resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range/Resolution 600.0 V / 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivoltsu00b9 true-rms Range/Resolution 600.0 mV / 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC voltsu00b9 true-rms Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range/Resolution 600 u03a9 / 1 u03a9
Accuracy Beeper on < 20 u03a9, off > 250 u03a9; detects opens or shorts of
500 μs or longer
Ohms Range/Resolution 600.0 u03a9 / 0.1 u03a9
6.000 ku03a9 / 0.001 ku03a9
60.00 ku03a9 / 0.01 ku03a9
600.0 ku03a9 / 0.1 ku03a9
6.000 Mu03a9 / 0.001 Mu03a9
Accuracy 0.9 % + 1
Range/Resolution 40.00 Mu03a9 / 0.01 Mu03a9
Accuracy 5 % + 2
Diode test Range/Resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz) Range/Resolution 6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/Resolution 6.000 A / 0.1 A10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)u00b2 Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2
A part of the review has been auto-translated.
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
A part of the QA has been auto-translated.